Home › Guides › Pool Heat Pump Not Heating? Common Causes and Fixes
Guide

Pool Heat Pump Not Heating? Common Causes and Fixes

Why a pool heat pump runs but will not heat, and what to check before you call: air temperature, water flow, run time, a blocked coil and the error codes that point to each.

The short answer
A pool heat pump that runs but will not heat usually has one of four problems: the air is too cold, water flow is too low, the pump is not running long enough, or the coil is blocked. Check those first. If the air coming out of the unit is 9 to 12°F cooler than the air going in, the heat pump is working and the pool needs more run time. An error code on the display points to the cause.

Quick Checks Before You Call

A heat pump that will not heat is often a setting, a dirty filter or a cold night, not a broken heater. Five minutes at the equipment pad can save a service call.

What you notice Usual cause What to check
Display is blank No power, or the pool pump is off Breaker, then whether the pool pump is running
Fan runs, water stays cold Not enough run time, or cold air Thermostat setting, pump schedule, overnight temperatures
FLO, PS or a flow light Low water flow Filter pressure, skimmer and pump baskets, valve positions
LP code Cold air, or a refrigerant problem Air temperature first; if it is mild, call for service
HP or HI code Restricted water flow Filter, closed valves, a bypass left open
Frost on the coil, deF code Normal defrost in cool weather Let it finish; it restarts on its own

Codes vary by brand and model, so treat these as the common families and confirm in your owner’s manual. If you have checked everything here and the pool is still cold, it is time for a repair call.

Is It Actually Broken? The Air Temperature Test

A heat pump does not create heat. It moves heat out of the air and into your water, which means the air leaving the unit should feel cooler than the air going in. AquaCal’s own check: if the difference is 9 to 12°F, the unit is doing its job.

When the heat pump passes this test but the pool is still cold, the problem is almost always run time. A heat pump only heats while the pool pump is pushing water through it, so a pump set to run a few hours a day cannot raise the water temperature much, especially in cooler weather.

Cold Snaps and Low Air Temperatures

Heat pumps work best in warm air, which is why they suit Florida. As the air cools, they make less heat per hour and need to run longer. Below a certain point they stop:

  • Hayward says its heat pumps operate efficiently down to around 45 to 50°F, and will cut off and show an LP code when it gets colder than that.
  • Defrost cycles are normal when outdoor temperatures drop into the mid-50s or below. You may see frost on the coil and a defrost code. The unit restarts on its own.

On the Treasure Coast, those cold stretches are usually short. The fix is patience and scheduling: run the heat pump during the warmest hours of the afternoon, and keep a solar cover on the pool at night so you keep the heat you paid for. If you need a pool or spa hot on demand in any weather, a gas heater is the tool for that job. Our heat pump page compares heat pumps, gas and solar.

Water Flow Problems

A heat pump needs steady water flow to run, and it protects itself by shutting down when flow drops. Low flow is the most common cause of a flow code, and it usually comes from something simple:

  • A dirty filter. Check the pressure gauge against its clean reading and clean the filter if it is high.
  • Full baskets. Empty the skimmer and pump baskets, especially after a windy week.
  • Valves in the wrong position. Make sure the valves to the heat pump are fully open and any bypass is closed.
  • The pool pump is off. Heat pumps will not operate when the pool pump is not running, so a timer or automation schedule that shuts the pump off also shuts off your heat.
  • A variable-speed pump set too low. This one catches a lot of owners. A low-speed setting that is fine for filtering may not move enough water for the heater. Hayward, for example, calls for at least 30 gallons per minute on its units. Your heat pump manual lists the minimum for your model.

Blocked Airflow

The heat pump pulls air through a coil on its sides and blows it out the top. Leaves, palm debris, overgrown landscaping or something stored against the unit all cut its output. AquaCal recommends clearing leaves, pine needles, twigs and anything else from the top and sides of the unit. Keep shrubs trimmed back so air moves freely.

When the Heat Pump Is Just Too Small

If the unit passes every check, runs long hours and still cannot hold the temperature you want, it may be undersized for the pool, especially if a spa or water feature has been added since it was installed. Sizing depends on the pool’s surface area, how warm you want it, and how much wind and shade the yard gets. Our guide to sizing a pool heater in Florida walks through the math.

Repair or Replace?

Some fixes belong to a technician, not an owner. Refrigerant leaks, failed sensors, fan motors and pressure switch problems all need diagnosis with the right tools, and refrigerant work requires a licensed technician.

A well-maintained heat pump commonly lasts about ten years. When an older unit has a refrigerant leak or a corroded coil, replacing it often makes more sense than repairing it. CoastLife Pools is an AquaCal dealer and also services Gulf Stream, Hayward, Jandy, Pentair and Raypak units, so we can register and handle warranty claims locally and give you a straight repair-or-replace answer.

Checked everything and still cold?

Book a service call →

Heat Pump Questions, Answered

Why is my pool heat pump running but not heating?
Usually because of cold air, low water flow, too little run time or a blocked coil. If the air leaving the unit is 9 to 12°F cooler than the air going in, the heat pump is working and the pool pump needs to run longer.
At what temperature does a pool heat pump stop working?
It depends on the model. Hayward says its units work efficiently down to around 45 to 50°F and cut off below that. Output drops well before the cutoff, so heating slows on cool nights.
How long should a heat pump take to heat my pool?
Heat pumps heat slowly and steadily. Time depends on pool size, the starting temperature, air temperature, wind and whether you use a cover. Running during the warmest hours and covering the pool at night shortens it considerably.
What does the FLO or PS code mean on my heat pump?
It means the unit is not getting enough water flow. Clean the filter and baskets, open the valves to the heat pump, close any bypass and make sure the pool pump is running at a high enough speed.
Is it normal for my heat pump to ice up?
Some frost in cool weather is normal, and the unit runs a defrost cycle to clear it. Frequent icing on mild days points to a sensor or refrigerant problem that needs a technician.